General information

Technological tanks, above ground, with type approval by the Central Office of Measures, meeting the requirements set out in the regulation of the Minister of Economy, Labour and Social Policy of 22 January 2008 on the metrological requirements to be met by measuring tanks. Some types of tanks - built before 2008 - meet only the older regulation from 2004.

Tanks made as single shell. When used as a storage tank for hazardous liquids (spirits), the ambient requirements specified in the regulation for the storage of flammable liquids must be met.

Capacitance measurement method used: tube liquid indicator with metal aperture.

Some tanks, of which we have the type designation, can be fitted with a high-speed side agitator with mechanical sealing.
The purpose of the tank: to carry out processing or storage of excisable agents.
The range of tanks with a GUM type designation is constantly expanding.

Zbiornik akcyzowy technologiczny V=3m³
Process excise tank V=3m³
Zbiornik akcyzowy technologiczny V=9m³. PLT 05134
Process excise tank V=9m³. PLT 05134
According to this type, we produce tanks with a capacity of V=1m³, V=9m³, V=17m³
Zbiornik akcyzowy technologiczny V=17m³ PLT 05134
Process excise tank V=17m³ PLT 05134
Zbiornik akcyzowy technologiczny V=35m³
Process excise tank V=35m³
Zbiornik akcyzowy technologiczny V=50m³
Process excise tank V=50m³

Application

Capacitance measurement method used:

  1. Tube liquid level gauge with metal divider No. PLT 05232,
  2. Mixed ribbon gauge with Class II accuracy weights No. PLT 06170.
Zbiornik akcyzowy technologiczny V=12m³
Process excise tank V=12m³

Application

Technological tank, above ground, with type approval by the Central Office of Measures, meeting the requirements set out in the regulation of the Minister of Economy, Labour and Social Policy of 22 January 2008 on the metrological requirements to be met by measuring tanks.

The tank is made as a single shell tank. When used as a storage tank for hazardous liquids (spirit), the ambient requirements specified in the regulation for the storage of flammable liquids must be met.

Capacitance measurement method used: tube liquid indicator with metal aperture.

Purpose of the tank: to carry out treatment processes - mixing, excisable agents.

Zbiornik akcyzowy technologiczny V=15m³
Process excise tank V=15m³
Zbiornik akcyzowy magazynowy wódki V=75m³
Excise vodka storage tank V=75m³
Zbiornik akcyzowy - zbiornik magazynowy spirytusu
Excise tank - spirit storage tank
Working volume V = 66m³

Application

By Decision No. 5/2010 of the President of the Central Office of Weights and Measures, a type of measuring tank for liquids with a nominal volume of 66m³ was approved.
The tank with a nominal volume of 66m³ is a ground-based, permanently sited tank. The tank has been given the type approval mark: PLT 105.
The tank meets the requirements set out in the regulation of the Minister of Economy of 22 January 2008 on the requirements to be met by measuring tanks.

Type characteristics
Shape of the tank cylinder with vertical principal axis
Type of tank roof fixed roof
Tank material stainless steel
Type of container non-pressure
Tank level measuring device liquid level gauge equipped with a rigid gauge having an elementary length of 1 mm
Number of liquid level indicator tubes three
Number of rigid liquid gauges three
Length of the liquid indicator tubes 3000 mm
Tank accessories spirit level (vial)
Internal diameter of the tank 3175 mm

The tank is non-thermally insulated, with the ambient and liquid temperatures in the tank not differing by more than 10°C.

Zbiornik akcyzowy - zbiornik magazynowy spirytusu - 35m³
Excise tank - spirit storage tank
Working volume V = 35m³

Application

By Decision No. 23/2009 of the President of the Central Office of Measures, a type of measuring tank for liquids with a nominal volume of 35m³ was approved.
The tank with a nominal capacity of 35m³ is an aboveground, permanently sited tank. The tank has been given the type approval mark: PLT 0921.
The tank meets the requirements set out in the regulation of the Minister of Economy of 22 January 2008 on the requirements to be met by measuring tanks.

Type characteristics
Shape of the tank cylinder with vertical principal axis
Type of tank roof fixed roof
Tank material stainless steel
Type of container non-pressure
Tank level measuring device mixed tape measure with 1 mm increments
Tank accessories clamping derrick of the web gauge, reference plate, spirit level (vial), manometer, overpressure or vacuum protection device.
Internal diameter of the tank 3000 mm